# IoT: PTP Time

Industry: IoT

Sensors, lidar and broadcast gear can share one clock over the Precision Time Protocol (PTP,
IEEE 1588). A device stamps each reading with a PTP timestamp. That timestamp counts TAI, which
has no leap seconds, so it is not UTC. A receiver turns it into UTC by subtracting an offset that
its grandmaster announces. If it skips that step, the data sits 37 seconds ahead of every other
clock, and nothing raises an error.

The functions here apply the announced offset in both directions and check the timestamp record.
They take the offset from the caller and never pick one.

```typescript
import { ptpToUtc, utcToPtp } from "@northguild/gmt/iot/convert";
import { isValidPtpTimestamp } from "@northguild/gmt/iot/validate";
```

The functions live in `@northguild/gmt/iot/convert` and `@northguild/gmt/iot/validate`.

## TAI on the wire

RFC 8877 section 4.3 says PTP "uses an 80-bit timestamp format". The nanoseconds take 32 bits,
so the 80-bit timestamp leaves 48 bits for the seconds. The RFC also says the timestamp is "not
affected by leap seconds". The count starts at 1970-01-01T00:00:00 TAI.

That is the same epoch value as Unix time, but a different time scale. UTC has stepped 27 times
since 1972 to stay near the Earth's rotation, and TAI has not. As of 2024, TAI is 37 seconds ahead
of UTC. Reading a PTP count as Unix seconds therefore gives a time 37 seconds ahead of the truth.

GMT holds the record as `{ seconds, nanoseconds }`. The seconds come back as a `bigint`, and a
safe-integer `number` is read too, because a 48-bit count fits in one.

## The announced offset

`currentUtcOffset` is TAI minus UTC, as a signed 16-bit integer. RFC 8575 defines it as the
`current-utc-offset` leaf of `time-properties-ds`, which the grandmaster announces. Reading it
out of an Announce message is IEEE 1588's job and is not reached here.

[`ptpToUtc(record, offset)`](/gmt/reference/iot/convert/ptpToUtc/) subtracts the offset and returns a
UTC instant string. [`utcToPtp(instant, offset)`](/gmt/reference/iot/convert/utcToPtp/) adds it back
and returns the record, or `null`. The two are inverses for the same offset.

```typescript
import { ptpToUtc, utcToPtp } from "@northguild/gmt/iot/convert";

ptpToUtc({ seconds: 1704067237n, nanoseconds: 0 }, 37);
// "2024-01-01T00:00:00Z"
utcToPtp("2024-01-01T00:00:00Z", 37);
// { seconds: 1704067237n, nanoseconds: 0 }
utcToPtp("2024-01-01T02:00:00+02:00", 37);
// { seconds: 1704067237n, nanoseconds: 0 } (a numeric offset in the input is read)
utcToPtp("2024-01-01T00:00:00.5Z", 37);
// { seconds: 1704067237n, nanoseconds: 500000000 }
```

The round trip gives the record it started with.

```typescript
import { ptpToUtc, utcToPtp } from "@northguild/gmt/iot/convert";

const utc = ptpToUtc({ seconds: 1704067237n, nanoseconds: 0 }, 37);
// "2024-01-01T00:00:00Z"

utcToPtp(utc, 37);
// { seconds: 1704067237n, nanoseconds: 0 }
```

## The 37-second error

Pass `0` and the function reads the count as a receiver does that ignores the offset. The result
is a valid instant, 37 seconds ahead.

```typescript
import { ptpToUtc } from "@northguild/gmt/iot/convert";

ptpToUtc({ seconds: 1704067237n, nanoseconds: 0 }, 37);
// "2024-01-01T00:00:00Z" (the right reading)
ptpToUtc({ seconds: 1704067237n, nanoseconds: 0 }, 0);
// "2024-01-01T00:00:37Z" (37 s ahead, and no error)
```

Nothing in the second result says it is wrong. The frames from a lidar that were stamped this way
sit 37 seconds ahead of the camera's. See
[A PTP Stamp 37 Seconds Ahead](/gmt/scenarios/a-ptp-stamp-37-seconds-ahead/).

## No default, on purpose

The offset has no default. In TypeScript, leaving it out is a type error. At run time, from
JavaScript or an `any`, it returns the sentinel for invalid input, and never a guess.

```typescript
import { ptpToUtc, utcToPtp } from "@northguild/gmt/iot/convert";

ptpToUtc({ seconds: 1704067237n, nanoseconds: 0 });
// ""
utcToPtp("2024-01-01T00:00:00Z");
// null
```

A default of 37 would be right today and wrong for any grandmaster that announces another value.
The offset must be an integer from -32768 to 32767, and `37.5` returns `""`.

## The flags beside the offset

RFC 8575's `time-properties-ds` announces three other values next to the offset.

- `ptp-timescale` false means the arbitrary time scale (ARB). The offset then has no meaning.
- `current-utc-offset-valid` false means the number is not valid.
- `time-traceable` says whether the time can be traced to a primary reference, so whether to
  trust the reading at all.

The library reads none of the three. The record carries only the count, and the function receives
only the offset, so it cannot see a flag. Check them before you call. If `ptpTimescale` is false or
`currentUtcOffsetValid` is false, do not call `ptpToUtc` with the number. In that state the number
may be stale, a default, or `0`, and passing a `0` through gives the 37-second error with no
warning.

## Checking a grandmaster against the table

The functions apply the offset you give them and never look up the leap-second table. To check
the grandmaster, compare the announced offset with what the table says for the reading, using
[`taiMinusUtc`](/gmt/reference/timescale/calculate/taiMinusUtc/) from `timescale`.

```typescript
import { ptpToUtc } from "@northguild/gmt/iot/convert";
import { taiMinusUtc } from "@northguild/gmt/timescale/calculate";

const record = { seconds: 1704067237n, nanoseconds: 0 };

const reading = ptpToUtc(record, 36);
// "2024-01-01T00:00:01Z" (a grandmaster still announcing the 2016 value)
taiMinusUtc(reading);
// 37 (not the 36 it announced)
```

The announced `36` was right until the end of 2016. The table says `37` for this date, so the two
disagree and the reading is 1 second out.

[`fromTAI`](/gmt/reference/timescale/convert/fromTAI/) from `timescale` converts through the table
and ignores the announcement. Use it when you want to know what UTC was, and use `ptpToUtc` when
you want to know what the receiver read. They differ exactly when the grandmaster is wrong.

```typescript
import { fromTAI } from "@northguild/gmt/timescale/convert";

fromTAI("2024-01-01T00:00:37 TAI");
// "2024-01-01T00:00:00Z" (what UTC was, whatever the grandmaster announced)
```

See [Leap seconds and TAI](/gmt/guides/core-date-operations/leap-seconds-and-tai/) for the table.

The lookup uses the announced reading, so within a second of a step it can be one second out. A
record stamped during the inserted second of 2016-12-31, read with the correct offset of `36`,
shows it.

```typescript
import { ptpToUtc } from "@northguild/gmt/iot/convert";
import { taiMinusUtc } from "@northguild/gmt/timescale/calculate";

const record = { seconds: 1483228836n, nanoseconds: 0 };

const reading = ptpToUtc(record, 36);
// "2017-01-01T00:00:00Z" (the function never writes a second of 60)
taiMinusUtc(reading);
// 37 (the table's answer for the next second, not the 36 announced)
```

## Before 1970, before 1972, and leap seconds

- **Before 1970.** A count smaller than the offset gives a result before the epoch, and
  `ptpToUtc` returns `""`. In practice this is a clock that was never set.
- **Before 1972.** UTC had no whole-second offset from TAI before 1972. The IERS file
  `Leap_Second.dat`, as of IERS Bulletin C 72, starts at 1972-01-01 with TAI − UTC at 10 seconds,
  and ITU-R TF.460-6 defines UTC from 1972. So `taiMinusUtc` returns `null` there and no offset is
  a true reading. The functions still do the arithmetic with the offset you pass.
- **A leap second.** `utcToPtp` refuses `…23:59:60Z`, because one offset for the whole call gives
  an inserted second no reading of its own. During an insertion, pass the newly announced offset.

```typescript
import { ptpToUtc, utcToPtp } from "@northguild/gmt/iot/convert";
import { taiMinusUtc } from "@northguild/gmt/timescale/calculate";

ptpToUtc({ seconds: 0n, nanoseconds: 0 }, 37);
// "" (before 1970: an unset clock)
ptpToUtc({ seconds: 37n, nanoseconds: 0 }, 37);
// "1970-01-01T00:00:00Z"
taiMinusUtc("1971-01-01T00:00:00Z");
// null (before 1972)
utcToPtp("2016-12-31T23:59:60Z", 37);
// null (a second of 60)
```

## Checking a record

[`isValidPtpTimestamp(value)`](/gmt/reference/iot/validate/isValidPtpTimestamp/) checks the record
against the ranges of the wire format. The `seconds` member is a `bigint` or a safe-integer
`number` from 0 to 2⁴⁸ − 1, and `nanoseconds` is an integer `number` from 0 to 999 999 999. Both
members are required. It is a type predicate, so it narrows `unknown` to a record.

```typescript
import { isValidPtpTimestamp } from "@northguild/gmt/iot/validate";

isValidPtpTimestamp({ seconds: 1704067237n, nanoseconds: 0 });
// true
isValidPtpTimestamp({ seconds: 1704067237, nanoseconds: 999999999 });
// true (number seconds)
isValidPtpTimestamp({ seconds: 281474976710656n, nanoseconds: 0 });
// false (2⁴⁸)
isValidPtpTimestamp({ seconds: 0n, nanoseconds: 1000000000 });
// false
isValidPtpTimestamp({ seconds: 0n });
// false (no nanoseconds)
isValidPtpTimestamp("2024-01-01T00:00:00Z");
// false
```

A record that passes can still convert to something before 1970. It checks the record, not a
conversion.

```typescript
import { ptpToUtc } from "@northguild/gmt/iot/convert";
import { isValidPtpTimestamp } from "@northguild/gmt/iot/validate";

isValidPtpTimestamp({ seconds: 0n, nanoseconds: 0 });
// true
ptpToUtc({ seconds: 0n, nanoseconds: 0 }, 37);
// "" (the result would be before 1970)
```

## What this layer does not do

- It does not parse an Announce message or any PTP message bytes. It starts from the seconds, the
  nanoseconds and the offset you have already read.
- It does not apply the rules of gPTP (IEEE 802.1AS). The same trap applies there, but its text
  was not reached, so GMT claims nothing about it. IEC/IEEE 61588 itself was also not reached.
- It does not look up the leap-second table inside `ptpToUtc` or `utcToPtp`. Checking the
  announcement against the table is your call to `taiMinusUtc`.
- It does not read `ptpTimescale`, `currentUtcOffsetValid` or `timeTraceable`. You check them.

## See it break, then work

- [A PTP Stamp 37 Seconds Ahead](/gmt/scenarios/a-ptp-stamp-37-seconds-ahead/)
- [IoT mistakes](/gmt/mistakes/iot/)
- [PTP Clock Converter](/gmt/tools/ptp-clock-converter/), a tool that reads a PTP timestamp as UTC, beside the same count with the offset ignored, and checks the offset against the table

## Sources

- IETF, [_RFC 8877_](https://www.rfc-editor.org/rfc/rfc8877), section 4.3: the 80-bit PTP
  timestamp, the epoch, and "not affected by leap seconds".
- IETF, [_RFC 8575_](https://www.rfc-editor.org/rfc/rfc8575), the `time-properties-ds` container:
  `current-utc-offset`, `current-utc-offset-valid`, `ptp-timescale` and `time-traceable`.
- IERS, `Leap_Second.dat`, and Bulletin C 72: TAI − UTC from 1972-01-01, the table `taiMinusUtc`
  reads.
- ITU-R Recommendation TF.460-6: UTC defined from 1972.
- IEC/IEEE 61588 (IEEE 1588): not reached. Its text, including how the Announce message carries
  the offset, is not cited.